Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Rev Bras Ortop (Sao Paulo) ; 58(6): e932-e938, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38077758

RESUMO

Objective To describe and evaluate the accuracy of the pericapsular nerve group (PENG) block technique with no ultrasound guidance. Method Series of 40 infiltrations in patients with hip pain undergoing outpatient follow-up in the hip surgery group or admitted to the emergency room from a hospital in São Paulo, SP, Brazil. The hip PENG technique was guided by palpable anatomical pelvic structures, with no ultrasound orientation for needle positioning, using the equipment only to check the correct location after an unguided puncture. Results In the 40 hips infiltrated from 35 patients with a mean age of 59.2 years, the success rate was 85%. Among the mispositioned cases, 71.4% occurred in the first 13 applications and 28.6% in the subsequent 27 applications. In all patients, the neurovascular bundle was in the medial third of the pen-made demarcation. Even in cases with a failed needle location, the distance from the neurovascular bundle was safe. A single adverse effect occurred, with spontaneous improvement of the femoral nerve apraxia within two days. Conclusion Unguided PENG block is a viable technique for a physician knowledgeable about its application in services with no ultrasound availability.

2.
Rev. bras. ortop ; 58(6): 932-938, 2023. graf
Artigo em Inglês | LILACS | ID: biblio-1535619

RESUMO

Abstract Objective To describe and evaluate the accuracy of the pericapsular nerve group (PENG) block technique with no ultrasound guidance. Method Series of 40 infiltrations in patients with hip pain undergoing outpatient follow-up in the hip surgery group or admitted to the emergency room from a hospital in São Paulo, SP, Brazil. The hip PENG technique was guided by palpable anatomical pelvic structures, with no ultrasound orientation for needle positioning, using the equipment only to check the correct location after an unguided puncture. Results In the 40 hips infiltrated from 35 patients with a mean age of 59.2 years, the success rate was 85%. Among the mispositioned cases, 71.4% occurred in the first 13 applications and 28.6% in the subsequent 27 applications. In all patients, the neurovascular bundle was in the medial third of the pen-made demarcation. Even in cases with a failed needle location, the distance from the neurovascular bundle was safe. A single adverse effect occurred, with spontaneous improvement of the femoral nerve apraxia within two days. Conclusion Unguided PENG block is a viable technique for a physician knowledgeable about its application in services with no ultrasound availability.


Resumo Objetivo Descrever e avaliar a acurácia da técnica do bloqueio PENG realizado sem auxílio de ultrassonografia. Método Série de 40 infiltrações em pacientes com dor no quadril, em acompanhamento ambulatorial no grupo de cirurgia do quadril ou admitidos no pronto atendimento de um hospital na cidade de São Paulo. Utilizada a técnica de bloqueio nervoso pericapsular do quadril (PENG) guiado por estruturas anatômicas palpáveis da pelve e sem auxílio de ultrassonografia no posicionamento da agulha, usando o aparelho apenas para conferência da localização correta após punção não guiada. Resultados Nos 40 quadris infiltrados em 35 pacientes com idade média de 59,2 anos, obtivemos um índice de acerto de 85%. Dos casos mal posicionados 71,4% ocorreram nas primeiras 13 aplicações e 28,6% nas 27 aplicações subsequentes. Em todos os pacientes o feixe neurovascular estava situado no terço medial da marcação realizada à caneta e mesmo nos casos em que houve falha da localização da agulha havia distância segura ao feixe neurovascular. Obtivemos apenas 1 caso de efeito adverso, onde ocorreu apraxia do nervo femoral com melhora espontânea em 2 dias. Conclusão O bloqueio PENG não guiado é uma técnica viável e pode ser realizada por um médico que já possui conhecimento na aplicação, em serviços onde não haja disponibilidade do aparelho de ultrassonografia.


Assuntos
Humanos , Complicações Pós-Operatórias , Infecção da Ferida Cirúrgica , Biomarcadores , Artroplastia do Joelho
3.
Rev. bras. ortop ; 57(5): 836-842, Sept.-Oct. 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1407709

RESUMO

Abstract Objective To correlate radiographic alterations and lesions in intra-articular structures of the acetabulum with the intensity of pain and disability of patients diagnosed with femoroacetabular impingement syndrome. Methods A retrospective analysis of the preoperative data of 182 patients (190 hips) was performed. Clinical variables such as age, gender, the practice of physical activity, and radiographic variables, such as the Wiberg and alpha angles, were evaluated. Through an intraoperative video, the extent of the chondral and labial lesions was evaluated considering the clock-face method, the degree of joint involvement by the Outerbridge classification, and the presence of wave lesions. The variables were analyzed by linear regression, with the intensity of the pain assessed by the Visual Analog Scale (VAS), and functional disability measured by the Modified Harris Hip Score (mHHS). Results The mean age of the patients was of 38.5 ± 9.6 years, the mean intensity of the pain was of 7.8 ± 1.6, and the mean mHHS score was of 56.3 ± 12.7. In total, 61% of the sample were classified as Outerbridge III or IV, and 12.6% had wave lesions. There was a correlation between the male gender (r = 0.497) and lower intensity of the pain, and a correlation of age (r = -0.27), the male gender (r = 8.419) and physical activity with higher functional scores on the mHHS (r = 4.729). Conclusion There was no correlation of the radiographic and arthroscopic parameters of the present study and the intensity of pain and the disability of the patients. The male gender is related to lower intensity of pain, and higher functional ability is related to the male gender, lower age, and the practice of physical activity. Level of Evidence IV.


Resumo Objetivo Correlacionar alterações radiográficas e lesões de estruturas intra-articulares do acetábulo com a intensidade da dor e a incapacidade de pacientes com diagnóstico de síndrome do impacto femoroacetabular. Métodos Realiou-se uma análise retrospectiva de dados pré-operatórios de 182 pacientes (190 quadris). Foram avaliadas variáveis clínicas como idade, sexo e prática de atividade física, e variáveis radiográficas, como ângulo de Wiberg e o ângulo alfa. Por meio do vídeo intraoperatório, foi avaliada a extensão das lesões condrais e labiais considerando-se o método clock-face, o grau de comprometimento articular pela classificação de Outerbridge, e a presença de lesão em onda. As variáveis foram analisadas por meio de regressão linear, tendo como variáveis dependentes a intensidade da dor, avaliada pela Escala Visual Analógica (EVA), e a incapacidade funcional, mensurada pelo Harris Hip Score modificado (HHSm). Resultados A média de idade dos pacientes foi de 38,5 ± 9,6 anos, a da intensidade da dor, 7,8 ± 1,6, e a do HHSm, 56,3 ± 12,7. No total, 61% da amostra apresentava Outerbridge III ou IV, e 12,6% apresentava lesão em onda. Observou-se correlação do sexo masculino (r = 0,497) com menor intensidade da dor, e correlação da idade (r = −0,27), do sexo masculino (r = 8,419) e da realização de atividade física com maior escore funcional no HHSm (r = 4,729). Conclusão Não houve correlação dos parâmetros radiográficos e artroscópicos deste estudo com a intensidade da dor e a incapacidade dos pacientes. O sexo masculino está relacionado com menor intensidade da dor, e maior capacidade funcional está relacionada com o sexo masculino, menor idade, e a prática de atividade física. Nível de Evidência IV.


Assuntos
Humanos , Masculino , Feminino , Medição da Dor , Artroplastia de Quadril , Impacto Femoroacetabular/diagnóstico
4.
Rev. bras. ortop ; 55(5): 523-531, Sept.-Oct. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1144206

RESUMO

Abstract The clinical diagnosis of femoral acetabular impingement (FAI) continues to evolve as the understanding of normal and pathological hips progresses. Femoral acetabular impingement is currently defined as a syndrome in which the diagnosis consists of the combination of a previously-obtained comprehensive clinical history, followed by a consistent and standardized physical examination with specific orthopedic maneuvers. Additionally, radiographic and tomographic examinations are used for the morphological evaluation of the hip, and to ascertain the existence of sequelae of childhood hip diseases and the presence of osteoarthritis. The understanding of the femoral and acetabular morphologies and versions associated with images of labral and osteochondral lesions obtained through magnetic resonance imaging (MRI) contributes to the confirmation of this syndrome in symptomatic patients, and helps in the exclusion of differential diagnoses such as iliopsoas tendon snaps, subspine impingement, ischiofemoral impingement, and other hip joint pathologies.


Resumo O diagnóstico clínico do impacto femoroacetabular continua a evoluir conforme o entendimento dos quadris normal e patológico progride. Impacto femoroacetabular é atualmente definido como uma síndrome na qual o diagnóstico se baseia no somatório de uma história clínica abrangente obtida previamente, seguida de um exame físico coerente e padronizado com manobras ortopédicas específicas. Além disso, exames radiográficos e tomográficos são usados para a avaliação morfológica do quadril, e para verificar a existência de sequelas de doenças do quadril da infância e a presença de osteoartrose. O entendimento da morfologia e versão femoral e acetabular associado às imagens de lesões labrais e osteocondrais obtidas com a ressonância magnética contribuem para a confirmação da síndrome nos pacientes sintomáticos, além de auxiliar na exclusão de diagnósticos diferenciais, como ressalto do tendão do músculo iliopsoas, impacto subespinhal, impacto isquiofemoral, e outras patologias da articulação do quadril.


Assuntos
Humanos , Exame Físico , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Diagnóstico Clínico , Diagnóstico Diferencial , Impacto Femoroacetabular , Quadril/diagnóstico por imagem , Articulação do Quadril
5.
Rev. bras. ortop ; 54(4): 428-433, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1042415

RESUMO

Abstract Objective The purpose of the present paper is to compare the equivalence of the measurement of the alpha angle using the Ducroquet and cross-table lateral views. Methods We have recruited 90 patients, resulting in 95 hips. We have standardized the realization of the radiographic views. The incidence of the lateral cross-table views were takenwith 15° of internal rotation with the patient in the supine position, and the incidence of the Ducroquet viewswas standardizedwith the patient in the supine position,with 90° of flexion and 45° of abduction of the hip. The alpha angle wasmeasured in both lateral views, by two musculoskeletal radiologists. The measurements were performed in 2 different times: an initial evaluation andanother 4weeks afterwards. The t Student test was usedand calculated the intraclass correlation coefficient (ICC). Results We have found a good intraobserver correlation for both views in different times; there was no statistically significant difference between the measurements performed by the two views. However, the interobserver correlation was low. Conclusion In conclusion, the Ducroquet profile view is a good choice for the α angle measurement and can be used instead of the cross-table view.


Resumo Objetivo O objetivo do presente trabalho é comparar a equivalência da medida do ângulo alfa do quadril usando as incidências laterais de Ducroquet e de cross-table. Método Estudamos 90 pacientes, com um total de 95 quadris, e padronizamos a realização das radiografias conhecidas como "Ducroquet" e "cross-table." A incidência de perfil de cross-table foi realizada em 15° de rotação interna com o paciente em posição supina, e a incidência de perfil de Ducroquet foi padronizada com o paciente posicionado em decúbito dorsal, em 90° de flexão e 45° de abdução do quadril. O ângulo alfa foi medido em ambas as radiografias de perfil, por dois radiologistas especializados em afecções musculoesqueléticas. As medidas foram realizadas em 2 épocas diferentes: uma avaliação inicial e outra após 4 semanas. O teste t de Student foi utilizado e calculou o coeficiente de correlação intraclasse (CCI). Resultados Encontramos boa correlação intraobservador para ambas as incidências radiográficas em diferentes momentos. Não houve diferença estatisticamente significante entre as medidas feitas pelas duas visualizações. No entanto, a correlação interobservadores foi baixa. Conclusão A incidência radiográfica de perfil de Ducroquet é uma boa opção para a medida do ângulo alfa e pode ser usada ao invés da incidência radiográfica de perfil cross-table.


Assuntos
Humanos , Masculino , Feminino , Radiografia , Impacto Femoroacetabular , Quadril/anormalidades , Quadril/diagnóstico por imagem
6.
Rev. bras. ortop ; 54(4): 477-482, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1042424

RESUMO

Abstract Objective To evaluate and compare the osteointegration of irradiated and nonirradiated frozen bone grafts used in 21 patients undergoing revision hip arthroplasty procedures with the Exeter technique. Methods A retrospective study of 21 patients undergoing revision hip arthroplasty with the Exeter technique using bone tissues treated or not with gamma radiation between 2013 and 2014. The patients were divided into two groups according to the use of grafts treated or not with ionizing radiation (gamma rays); as such, these groups were classified as irradiated or non-irradiated. The osteointegration results determined by radiographic analysis of these grafts were compared in the postoperative period of 6 and 12months. Results Comparing the graft osteointegration in all patients at 6 and 12months postoperatively, we noticed a significant difference in the radiographic evaluations in this period (p = 0.031). Out of the patients studied, 7 were from the irradiated group, and 14 belonged to the non-irradiated group. No statistically significant differences were observed (p = 0.804) regarding osteointegration when we compared the irradiated and non-irradiated groups. Conclusion There was no significant difference in the use of irradiated or nonirradiated grafts in revision hip arthroplasty procedures with the Exeter technique.


Resumo Objetivo Avaliar e comparar a osteointegração dos enxertos ósseos congelados irradiados e não irradiados utilizados em 21 pacientes submetidos a revisão de prótese do quadril pela técnica Exeter. Métodos Foi realizado estudo retrospectivo de 21 pacientes submetidos a revisão de artroplastia do quadril pela técnica Exeter comutilização de tecidos ósseos tratados ou não com radiação gama no período entre 2013 e 2014. Dividimos os pacientes em dois grupos, de acordo com o uso do enxerto tratado ou não com radiação ionizante (raios gama), que foram, portanto, classificados como: grupo irradiado e não irradiado. Os resultados da osteointegração por análise radiográfica destes enxertos foram comparados no pós-cirúrgico de 6 e 12 meses. Resultados Quando comparamos a osteointegração dos enxertos no pós-cirúrgico de 6 e 12 meses de todos os pacientes, notamos que houve diferença significativa entre as avaliações radiográficas neste período (p= 0,031). Dos pacientes estudados, 7 pertenciam ao grupo irradiado, e 14, ao grupo não irradiado. Não foram observadas diferenças estatisticamente significativas (p= 0,804) quando a osteointegração entre os grupos irradiados e não irradiados foi comparada. Conclusão Não houve diferença significativa no uso de enxerto irradiado e não irradiado nas revisões de artroplastias do quadril pela técnica Exeter.


Assuntos
Humanos , Masculino , Feminino , Artroplastia , Bancos de Tecidos , Osseointegração , Enxertos Osso-Tendão Patelar-Osso
7.
Rev. bras. ortop ; 51(4): 412-417, July-Aug. 2016. graf
Artigo em Inglês | LILACS | ID: lil-792728

RESUMO

ABSTRACT OBJECTIVE: The aim of this study was to determine the acetabular bone lesion size (in millimeters) from which impacted bone graft failure starts to occur more frequently, through simple anteroposterior hip radiographs, and whether measurement of the defect on simple radiographs maintains the same pattern in inter and intraobserver assessments. METHODS: Thirty-eight anteroposterior pelvic-view radiographs from patients undergoing revision of an acetabular prosthesis were retrospectively analyzed and assessed. In the vertical plane, the bilacrimal line was measured in millimeters from the farthest point found on the bone edge of the acetabular osteolysis to the top edge of the cementation or of the acetabular implant in uncemented cases. The base was taken to be a line perpendicular to bilacrimal line, with the aim of eliminating any pelvic tilt effects. This measurement was named the vertical size of failure. Radiographs produced four years after the operation were analyzed to investigate any failure of the technique. RESULTS: The graft failure rate in the study group was 26.3%. The failures occurred in cases with an initial bone defect larger than 11 mm. No cases with measurements smaller than this evolved with failure of the revision. The highest incidence of graft failure occurred in cases described as advanced according to the "Paprosky" classification. CONCLUSION: Failure of acetabular revision arthroplasty using an impacted graft did not present any statistically significant correlation with the vertical extent of the lesion on simple anteroposterior radiographs, as a predictor of treatment failure.


RESUMO OBJETIVO: O presente trabalho buscou, através de uma radiografia simples anteroposterior do quadril, quantificar em milímetros a partir de qual tamanho da lesão óssea acetabular ocorre com maior frequência falha do enxerto ósseo impactado e se a medição do defeito nas radiografias simples mantém o mesmo padrão na avaliação inter e intraobservador. MÉTODOS: Foram analisadas e aferidas retrospectivamente 38 radiografias de pacientes submetidos à revisão de prótese acetabular na incidência anteroposterior de bacia, mensurando em milímetros, no plano vertical a linha bilacrimal, a medida entre o ponto mais distante encontrado na borda óssea da osteolise acetabular, com a margem superior da cimentação ou implante acetabular nos casos não cimentados. Tomamos como base uma linha perpendicular a linha bilacrimal com o intuito de eliminar efeitos de inclinação pelvic. Essa medida foi denominada Tamanho Vertical da Falha. Radiografias pós-operatórias com quatro anos foram analisadas para averiguar falha da técnica. RESULTADOS: No grupo estudado observamos 26,3% de falhas do enxerto que ocorreram a partir de 11 mm de tamanho da falha óssea inicial mensurada e que abaixo desse valor nenhum caso evoluiu com falha da revisão. A maior incidência da falha do enxerto ocorreu nos casos avançados segundo a classificação de Paprosky. CONCLUSÃO: A falha na artroplastia de revisão acetabular com enxerto impactado quando relacionado à medida vertical da lesão em radiografia simples anteroposterior do quadril não apresentou significância estatística como fator preditivo de falha do tratamento.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Acetábulo , Aloenxertos , Artroplastia de Quadril , Transplante Ósseo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA